Radiator BTU calculator

Find the heat a room needs in watts and BTU from its size, use, windows and insulation, then see the radiator rating to look for. A guide for choosing radiators, not a full heat loss survey.

Your room

Leave at ΔT 50 unless the system runs at lower water temperatures, as heat pumps often do.

Insulation
Anything else about the room?

Heat needed

Radiator outputs are quoted at ΔT 50 under BS EN 442. Compare the rated output on the product sheet with the figure above, and split it across two radiators in a large room if needed.

How the radiator BTU calculation works

The calculator follows the room volume method published by radiator supplier BestHeating. The length, width and ceiling height are multiplied to give the room's volume in cubic metres. That volume is multiplied by a heat loss figure for the type of room, in watts per cubic metre, to give the heat the room needs. Adjustments are then added or taken away for large windows, insulation, a north-facing aspect and open-plan layouts. Watts are converted to BTU by multiplying by 3.41.

Because the published figures are ranges, the result is a range too. A worked example: a living room 5m long, 4m wide and 2.4m high is 48 m³. At 50 to 60 watts per m³ it needs 2,400 to 2,880 watts. If it faces north, adding 10% gives 2,640 to 3,168 watts, which is about 9,002 to 10,803 BTU. A radiator, or a pair of radiators, rated at around 3,200 watts at ΔT 50 would cover the top of that range.

What changes the result

Room size and ceiling height

Volume drives the result, so a high ceiling raises the figure directly. The calculator uses the real ceiling height, which is why it does not add a separate high-ceiling allowance on top.

How the room is used

Bathrooms carry the highest figure at 60 to 70 watts per m³ and bedrooms the lowest at 40 to 50. Viessmann notes that bedrooms are typically kept at 16 to 18°C, with living rooms around 2 to 3 degrees warmer, which is part of the reason the figures differ.

Windows, insulation and aspect

BestHeating suggests adding 10 to 20% for large windows or patio doors, 15 to 25% for poor insulation, 10% for a north-facing room and 15 to 25% for open-plan dining and living, and taking 5 to 10% off for a well insulated room. The calculator adds the chosen percentages together.

Water temperature (Delta T)

Radiator outputs are tested and quoted at ΔT 50 under EN 442. Delta T is the average of the flow and return water temperatures minus the room temperature, so ΔT 50 is, for example, 75°C flow and 65°C return in a 20°C room. A system running cooler gives less heat from the same radiator. Using the n coefficient of 1.3 published by Zehnder, the output at other Delta T values is:

System Delta TShare of the ΔT 50 output
ΔT 50100.0%
ΔT 4587.2%
ΔT 4074.8%
ΔT 3562.9%
ΔT 3051.5%

To find the ΔT 50 rating to look for, the calculator divides the room's need by that share. At ΔT 30 that roughly doubles the rating required.

Common mistakes and tips

  • Comparing different Delta T ratings. Some retailers quote ΔT 60 figures, which look higher. Check that the radiator's output is quoted at ΔT 50 before comparing it with the result.
  • Measuring floor area only. The method uses volume, so include the ceiling height.
  • Choosing by size rather than output. Two radiators of the same size can give very different outputs depending on panels and fins, so check the watts or BTU on the product sheet.
  • Ignoring the boiler or heat pump. New radiators only help if the heat source and pipework can supply them, so changes across the whole house are best planned with a heating engineer.
  • Treating the result as exact. The method is a rule of thumb. A room-by-room heat loss calculation is more accurate, especially for a heat pump.

When to get a professional

Swapping a radiator for one of similar output is a common job for a plumber or heating engineer. Larger changes, such as resizing radiators for a heat pump, adding radiators to an extension or fixing rooms that never get warm, need a proper heat loss calculation and a check of the boiler, pump and pipe sizes. A Gas Safe registered engineer is needed for any work on a gas boiler.

Replacing or adding radiators? Compare well reviewed local plumbers and heating engineers.

Find a top rated plumber near you

How this is worked out

  • Volume (m³) = length x width x ceiling height.
  • Watts = volume x heat loss figure for the room type (low and high) x (1 + total adjustment % / 100).
  • BTU = watts x 3.41.
  • ΔT 50 rating to look for = watts / (system ΔT / 50)1.3.
Room typeWatts per m³
Living room50 to 60
Bedroom40 to 50
Bathroom60 to 70
Kitchen50 to 60
Dining room50 to 60
Home office45 to 55
AdjustmentChange
Large windows or patio doors+10% to +20%
North-facing room+10%
Open-plan dining and living+15% to +25%
Poor insulation+15% to +25%
Well insulated-10% to -5%
  • BestHeating, BTU and radiator size guide: what size radiator do I need (updated 1 September 2026, checked 9 November 2026). Room volume in m³ multiplied by a heat loss figure per room type (living room 50 to 60, bedroom 40 to 50, bathroom 60 to 70, kitchen 50 to 60, dining room 50 to 60, home office 45 to 55) to give watts; adjustments for large windows, insulation, north-facing and open-plan rooms; 1 watt = 3.41 BTU; most UK radiators are rated at Delta T 50.
  • Zehnder, correction factors and Delta T conversion (checked 9 November 2026). Radiators are tested to EN 442 and outputs published at ΔT 50; ΔT = (flow temperature + return temperature) / 2 minus room temperature; conversion uses an n coefficient of 1.3.
  • Viessmann, how many BTU to heat a room (31 May 2022, checked 9 November 2026). Bedrooms are typically kept at 16 to 18°C and living rooms around 2 to 3 degrees warmer; insulation and ceiling height change the heat a room needs.

Related guides

Radiator sizing questions

How many BTU do I need for a bedroom?

Using BestHeating's figure of 40 to 50 watts per cubic metre for bedrooms, a 4m x 3.5m bedroom with a 2.4m ceiling (33.6 m³) needs about 1,344 to 1,680 watts, or roughly 4,583 to 5,729 BTU. BestHeating gives about 3,500 to 5,000 BTU for a small bedroom of 2.5m x 3m.

How many BTU do I need for a living room?

At 50 to 60 watts per cubic metre, a 5m x 4m living room with a 2.4m ceiling (48 m³) needs about 2,400 to 2,880 watts, or 8,184 to 9,821 BTU. If it faces north, BestHeating suggests adding 10%, which gives 2,640 to 3,168 watts.

How do I convert watts to BTU?

Multiply watts by 3.41 to get BTU per hour, the conversion BestHeating uses. To go the other way, divide BTU by 3.41. A 1,500 watt radiator is about 5,115 BTU.

What does Delta T 50 mean on a radiator?

It is the rating condition used under EN 442. Delta T is the average of the flow and return water temperatures minus the room temperature, so ΔT 50 is, for example, water flowing at 75°C and returning at 65°C in a 20°C room. Zehnder states that it publishes outputs at ΔT 50 in line with EN 442.

Do radiators need to be bigger for a heat pump?

Often, because heat pumps usually run at lower water temperatures, which lowers Delta T. With the n coefficient of 1.3 that Zehnder uses, a radiator at ΔT 30 gives about 51% of its ΔT 50 output, so it needs a ΔT 50 rating about twice the room's heat need. A heating engineer should size radiators for a heat pump with a room-by-room heat loss calculation.

Need radiators fitted or a heating system checked? Compare well reviewed plumbers near you.

Find a top rated plumber near you