The Water Supply (Water Fittings) Regulations 1999 are a strict legal requirement in England and Wales. Regulation 5 means some listed jobs must be notified to the water supplier before they start, while most everyday jobs are not on the list.
What the water regulations are
The Water Supply (Water Fittings) Regulations 1999 are a law, not a qualification and not a scheme. A plumber cannot choose to take them, and a company cannot opt into them. In England and Wales, regulation 3(2) says no water fitting shall be installed, connected, arranged or used in such a manner that it causes or is likely to cause waste, misuse, undue consumption or contamination of water supplied by a water undertaker or water supply licensee, or the erroneous measurement of that water. Regulation 3(3) applies the same rule to a fitting that is damaged, worn or otherwise faulty.
In England and Wales, regulation 4 says every water fitting shall be of an appropriate quality and standard and suitable for the circumstances in which it is used. A fitting is of an appropriate quality or standard only if it conforms to an appropriate British Standard or some other national specification providing an equivalent level of protection and performance, or to a specification approved by the regulator.
Regulation 10 (England and Wales) says a water undertaker shall enforce the requirements of the Regulations in relation to the area for which it holds an appointment. The duty is enforceable by the regulator under section 18 of the Water Industry Act 1991.
Where the rules apply
The 1999 Regulations apply in England and Wales. Under regulation 2, they concern water fittings in premises to which water is supplied by a water undertaker or water supply licensee. They do not apply to certain metered temporary supplies for purposes other than domestic or food production.
Except for paragraph 14 of Schedule 2, the Regulations do not apply to fittings that are not connected to water supplied by a water undertaker or licensee.
Under regulation 2(4), nothing in the Regulations requires any person to remove, replace, alter, disconnect or cease to use any water fitting which was lawfully installed or used, or capable of being used, before 1st July 1999.
Work that must be notified first
When you plan a plumbing project, you must check if it needs official permission. Regulation 5 states that any person who proposes to install a water fitting in connection with certain operations must give notice. You must give this formal notice to the water undertaker for your region. You have to tell them clearly that you propose to begin work. You must not begin the work without the undertaker granting their official consent. Once consent is given, you must comply with any conditions of the consent. Regulation 5(4) and 5(5), below, deal with how consent is given, and regulation 5(2) sets out an exemption for approved contractors.
The law lists these specific operations in the regulation 5 Table. Most everyday plumbing jobs are not on this list.
This table shows the operations listed in the regulation 5 Table that require notice.
|
Item number |
What the operation covers |
|---|---|
|
1 |
The erection of a building or other structure, not being a pond or swimming pool |
|
2 |
The extension or alteration of a water system on any premises other than a house |
|
3 |
A material change of use of any premises |
|
4 |
The installation of the fittings listed in paragraphs 4(a) to 4(i), set out below |
|
5 |
The construction of a pond or swimming pool with a capacity greater than 10,000 litres which is designed to be replenished by automatic means and is to be filled with water supplied by a water undertaker or water supply licensee |
Item 4 covers the installation of each of the following:
- 4(a) A bath with a capacity, measured to the centre line of the overflow, of more than 230 litres.
- 4(b) A bidet with an ascending spray or flexible hose.
- 4(c) A single shower unit, not a drench shower installed for safety or health, connected directly or indirectly to a supply pipe of a type specified by the regulator.
- 4(d) A pump or booster drawing more than 12 litres per minute connected directly or indirectly to a supply pipe.
- 4(e) A unit which incorporates reverse osmosis.
- 4(f) A water treatment unit which produces a waste water discharge or requires water for regeneration or cleaning.
- 4(g) A reduced pressure zone valve assembly or other mechanical device for protection against a fluid in fluid category 4 or 5.
- 4(h) A garden watering system unless it is designed to be operated by hand.
- 4(i) Any water system laid outside a building and either less than 750mm or more than 1350mm below ground level.
What the water supplier can do with your notice
Under regulation 5(4), the water undertaker may withhold consent, or grant it subject to conditions, by a notice given before the expiry of the period of ten working days commencing with the day on which notice was given.
The regulations say consent shall not be withheld unreasonably. Under regulation 5(5), if no notice is given by the water undertaker within the ten working day period, the consent required under regulation 5(1) is deemed to have been granted unconditionally.
Regulation 13 (England and Wales) covers a dispute between a water undertaker and a person who has installed or proposes to install a water fitting about whether the undertaker has unreasonably withheld consent or attached unreasonable conditions under regulation 5. It shall be referred to arbitration by a single arbitrator, who is appointed by agreement or, in default, by the regulator.
What an approved contractor changes
Using an approved professional changes how some of the notification rules work in practice. Regulation 1 defines what an approved contractor actually is under the law. It is a person who has been approved by the water undertaker for the local area where the water fitting is installed or used. It can also be a person who has been certified as an approved contractor by an organization specified in writing by the regulator. The guide on how WaterSafe works explains how to search for approved contractors. WaterSafe says approved contractors can carry out certain work without prior notification to water suppliers.
The exemption is in regulation 5(2). The rule requiring advance notice does not apply to the installation by an approved contractor of a water fitting falling within three specific parts of the Table. These are paragraph 2, paragraph 4(b), and paragraph 4(g). It is vital to understand that for all the other listed jobs in the Table, the notice rule still applies exactly as normal. You must still notify the undertaker for those other jobs, even when an approved contractor is used.
When you do have to submit a notice, regulation 5(3) sets out exactly what paperwork is needed:
- The name and address of the person giving the notice.
- A description of the proposed work or the material change of use.
- Particulars of the location and the use of the premises.
- A plan of the relevant parts of the premises.
- A diagram showing the pipework and fitting to be installed.
- The contractor's name where an approved contractor does the work, as required by regulation 5(3)(e).
The plan and diagram are not required for fittings under paragraph 4(a), 4(c), 4(h), or 5 of the Table.
When the job is completely finished, regulation 6 applies. On completion of the work, the contractor furnishes a signed certificate. This certificate states whether the water fitting complies with the regulations. They must give this document to the person who commissioned the work. For a fitting that needed notice under regulation 5(1), the contractor also sends a copy of the certificate directly to the water undertaker. WaterSafe confirms that their approved contractors issue these Certificates of Compliance.
Regulation 7(2) (England and Wales) says that in proceedings against an owner or occupier, it is a defence to prove that the work was carried out by or under the direction of an approved contractor, and that the contractor certified to the person who commissioned the work that the water fitting complied with the Regulations.
Scotland and Northern Ireland
The 1999 Regulations apply in England and Wales. The website waterregsuk.co.uk presents itself as 'All you need to know about the UK water fittings regulations & byelaws', with separate sections titled 'Requirements England & Wales', 'Requirements Scotland' and 'Requirements NI'. It describes its content as informative, non-statutory guidance and points to the official legislation text, which is the place to check the actual law for Scotland or Northern Ireland.
For Scotland, waterregsuk.co.uk gives the Water Supply (Water Fittings) (Scotland) Byelaws 2014, covering premises supplied by Scottish Water. It says byelaw 5 requires notice to and consent from Scottish Water for listed works, and byelaw 6 requires approved contractors to certify completed work.
For Northern Ireland, waterregsuk.co.uk gives the Water Supply (Water Fittings) Regulations (Northern Ireland) 2009, in operation on 3rd August 2009 and replacing the Water Regulations (Northern Ireland) 1991. It says regulation 5 requires notice and consent for specified work and regulation 6 requires approved contractors to give a signed certificate of compliance.
Asking whether a job is notifiable
The question to put to a plumber is 'Is this job notifiable and who will notify?'. The answer depends on whether the job is in the regulation 5 Table, and on who is doing the work, since regulation 5(3) puts an approved contractor's name in the notice. When a plumber says a job is notifiable, ask who will give the notice to the water undertaker. The regulations do not say a homeowner must hold a qualification.
Common questions
What is backflow protection and why is it needed?
Backflow occurs when fluid flows in the opposite to the intended or normal direction of flow.
Do bathroom taps require special backflow protection?
waterregsuk.co.uk says all water fittings in a bathroom must be supplied via backflow protection rated equal to or higher than the highest downstream contamination risk. It says typically bath and basin taps in domestic premises are 'categorised as a fluid category 3 risk' but 'ultimately it is for the local water undertaker to determine what level of backflow protection is required'.
Are outside hose union taps allowed under the rules?
waterregsuk.co.uk says a hose union tap is 'a tap to which a hose can be connected' and that hoses attached to them 'are considered to be a high contamination risk'. It adds that a hose union tap incorporating a double check valve (Type HUK1) 'can only be lawfully used if installed prior to 1st July 1999'. Costs for a new outside tap are covered in our outside tap installation cost guide.
Next steps for your plumbing project
These points follow from the regulations above:
- Check if your planned work falls under the regulation 5 Table of notifiable operations.
- Ask 'Is this job notifiable and who will notify?'.
- If notice is needed, do not start until consent has been given or is deemed granted after ten working days with no notice from the undertaker.
- Ensure you receive a signed certificate of compliance when the job is finished.
The regulations are a law that applies in England and Wales, and the Table in regulation 5 is the list to check. When you are ready to move forward with your project, you can find a plumber near you.
Find a top rated plumber near you
4,869 plumbers across the UK, each ranked on their Google rating and the number of reviews behind it. Start with your county: